"When CVS is encountered, catheter management should be individualized through MDT assessment, and retention of a PICC in a nonstandard tip position should be regarded as an exceptional strategy" Wu et al (2026).
Study typeCase report
PopulationOne 57-year-old woman with recurrent breast cancer
DevicePeripherally inserted central catheter via left basilic vein
OutcomeStenosis found; nonstandard tip kept, dislodgement but no thrombosis or infection

Summary

Wu and colleagues report a case of central vein stenosis found during a second peripherally inserted central catheter placement in a 57-year-old woman with recurrent right breast cancer who needed long-term access for systemic anticancer treatment. Catheter advancement through the left basilic vein was impeded, and venography showed left brachiocephalic vein stenosis with coiling. A multidisciplinary team withdrew the catheter, leaving the tip in the left subclavian vein, and kept it with individualised anticoagulation and surveillance. Over about six months, the catheter was dislodged, but no thrombosis, infection or extravasation was documented.

Why this matters for practice

Central vein stenosis can be missed when peripheral veins look patent, so unexpected resistance during catheter advancement may be an early sign. This case suggests that teams may want to treat resistance as a prompt to assess the central veins rather than continue to advance the catheter.

The authors describe a multidisciplinary decision to keep the catheter in a nonstandard tip position and describe this as an exceptional strategy. It is a single case with limited follow-up, so services may wish to review local escalation routes, documentation of tip position decisions and surveillance arrangements when a standard central tip cannot be achieved.

Key takeaways

  • Resistance during PICC advancement may signal central venous abnormality.
  • Peripheral veins can appear patent despite central vein stenosis.
  • Venography confirmed left brachiocephalic vein stenosis with catheter coiling.
  • A multidisciplinary team guided the decision on tip position.
  • Nonstandard tip retention was described as an exceptional strategy.

Study abstract

Central vein stenosis (CVS) can complicate peripherally inserted central catheter (PICC) placement by impeding catheter advancement and preventing achievement of an appropriate central tip position. On 23 January 2025, a 57-year-old female with recurrent right breast cancer was admitted for systemic anticancer treatment and required renewed long-term venous access. During a second PICC placement through the left basilic vein, catheter advancement was unexpectedly impeded, and venography confirmed left brachiocephalic vein stenosis with catheter coiling near the stenotic segment. A multidisciplinary team (MDT), including PICC specialist nurses, oncology physicians, cardiovascular surgeons, and ultrasound imaging experts, determined that further advancement across the left stenotic segment posed additional risk. The catheter was therefore withdrawn until the coiling resolved, leaving the tip in the left subclavian vein. After individualized assessment of the patient's vascular anatomy, treatment requirements, and alternative vascular access options, the catheter was retained at this nonstandard tip position and managed with individualized anticoagulation and clinical surveillance. During approximately six months of follow-up, the patient experienced catheter dislodgement, but no clinically documented catheter-related thrombosis, infection, or drug extravasation occurred. The case highlights that unexpected resistance during PICC advancement may warrant assessment for central venous abnormalities even when peripheral veins appear patent. When CVS is encountered, catheter management should be individualized through MDT assessment, and retention of a PICC in a nonstandard tip position should be regarded as an exceptional strategy.

— Wu et al (2026)

Reference and full text

Wu H, Li Y, Ding J, Huang Q, Chen X, Tang L. Central vein stenosis detected during a second peripherally inserted central catheter placement in a patient with recurrent breast cancer: a case report. Front Oncol. 2026;16:1881442.

DOI: 10.3389/fonc.2026.1881442 · PMID: 43060982 · PMCID: PMC13781724

Read the full text (free)

Related on IVTEAM

IVTEAM summaries are for education and do not replace local policy or clinical judgement. Copyright in the original article remains with the authors and publisher.