Predictors of successful long-term hemodialysis access outcomes

vascular access

“Understanding predictors of successful long-term access outcomes can guide decision-making regarding access type and alternative strategies. In our cohort, increased age and prior central venous catheter placement are associated with a shorter time to failure of permanent hemodialysis access and an increased risk of needing revision” Talebi et al (2024).

Improved CLABSI prevention bundles

IVTEAM Intravenous Literature

“Sensitizing physicians to the existence and duration of CVCs accompanied with improved bundle-prevention measures, resulted in reduction of pCVCs, and outside the ICU, also in reduction of CVC-UR and CLABSI rates” Regev et al (2024).

Using central venous access devices outside of ICU settings

central line

“Reliable and long-lasting venous access in children is preferred outside the ICU settings where CVADs are essential for long-term treatment involving administration of long-term nutrition in gut enteropathies, chemotherapy, hemodialysis as well as in palliative situations requiring pain medications or administration of antibiotics as in chronic osteomyelitis” Rajkumar et al (2024).

IV catheter foreign body found in heart – Full Text

vascular access

“Health care professionals must check upon removal of peripheral intravenous access, and record whether the integrity of the peripheral catheter tip was compromised to prevent similar events in future” Şahin et al (2024).

Impact of inappropriate central line blood cultures

blood sampling

“The infectious diseases service was consulted for possible catheter related bloodstream infection (CRBSI). The consultant determined that the risk of CRBSI was low because the tunneled line was nontender without surrounding erythema or drainage, and the patient had a known alternative source of infection” Fuher et al (2024).

Potential bias in hospital-based transfusion medicine

transfusion

“Hospital-based transfusion involves hundreds of daily medical decisions. Medical decision-making under uncertainty is susceptible to cognitive biases which can lead to systematic errors of reasoning and suboptimal patient care” Raza et al (2024).

ICU integrated management model improves medication safety – Full Text

IVTEAM Intravenous Literature

“The Integrated Management Model of Doctor-Nurse-Pharmacist Collaboration significantly reduced the incidence of catheter-related bloodstream infections (CRBSI), drug incompatibility, and other intravenous therapy-related complications, thereby enhancing the safety of intravenous therapy in critically ill patients” Gao et al (2024).

Medication administration errors in neonatal intensive care units – Full Text

Drug administration

“This study developed and validated an ML-based model to predict the presence of MAEs among neonates in NICUs. AdaBoost was identified as the best-performing algorithm. Utilising the model’s predictions, healthcare providers can potentially reduce MAE occurrence through timely interventions” Henry Basil et al (2024).

Flushing interval for totally implantable venous access ports – Full Text

iv flush

“The incidence and burden of intraluminal clots did not increase significantly within the first 3 months. Occlusion was rare, even in the presence of clots, and was successfully treated. Therefore, a 3-month flushing interval appears to be a safe and practical option, aligning with the common recommendation for surveillance intervals in patients with cancer” Yang et al (2024).

Review of peripheral IV catheter failure in the ED – Full Text

peripheral iv

“This study identified a prevalence of PVC failure in the ED of around 1%. The most prevalent complication was dysfunction, followed by extravasation and dislodgement. In addition, PVC failure was associated with comorbidity/complications, psycho-emotional and mental-cognitive CCIFs domains” Urbina et al (2024).

Drug delivery during syringe pump change over

Infusion pump

“In a simulated environment with a cardiac output of 5 L/min, the CVP level and vertical position of the syringe pump generated bolus or backflow events during the syringe pump changeover” Lucchini et al (2024).

Intravenous line labels for high-alert drugs

drug aministration

“The label can be used as a technology to prevent misidentification of high-alert medications administered to critically ill patients through intravenous lines, thereby enhancing medication safety in healthcare institutions” de Kassio Nunes et al (2024).

CLABSI reduction in preterm neonates

clabsi

“To compare the incidence of central line associated blood stream infections (CLABSI) with the use of umbilical venous catheters (UVC) as primary vascular access in preterm neonates with peripherally inserted central catheters (PICC)” Arun et al (2024).

Safety of peripherally infused vasopressors

drug aministration

“Peripherally infused sympathomimetic vasopressors are safe to administer up to 24 hours with a low incidence of extravasation events while avoiding CVC placement in the majority of patients” Zichichi et al (2024).

Ultrasound-guided CVC placement-related complications in neonates

ultrasound guided vascular access

“No significant difference was detected in the incidence of hematoma or venous thrombosis between the control and ultrasound groups. Other complications, such as pneumothorax, hemothorax, phlebitis, and cardiac tamponade, rarely occurred” Cui et al (2024).

IV and subcutaneous modes of administration in oncology patients

drug aministration

“Compared with IV administration, SC oncology treatment is a preferred option by patients and HCPs, increasing optionality and reducing treatment time while simultaneously increasing capacity and reducing the financial burden on healthcare systems” Aguiar-Ibáñez et al (2024).

Detection of infusion-related microplastics

IVTEAM Intravenous Literature

“This work examined the content, type, shape, and size of M/NPs released directly into the bloodstream from medical devices via saline solution during intravenous (IV) injection” Mou et al (2024).