Inadvertent subclavian artery cannulation with a central venous catheter

jugular vein size

“A 48-year-old lady was referred to our department as an emergency following an unsuccessful attempt at central venous catheter insertion, resulting in cannulation of the subclavian artery.” Redmond et al (2014). Reference: Redmond, C.E., O’Donohoe, R., Breslin, D. and Brophy, D.P. (2014) Inadvertent subclavian artery cannulation with a central venous catheter; successful retrieval using a […]

Article describes the assessment of hydration status

intravenous fluids

“The assessment of hydration status in a large sample appears to be of interest for conducting epidemiological and large clinical studies aimed at improving preventive and curative care.” Baron et al (2014). Reference: Baron, S., Courbebaisse, M., Lepicard, E.M. and Friedlander, G. (2014) Assessment of hydration status in a large population. The British Journal of […]

OPAT programs provide framework for safe and effective care

opat

“Formal OPAT programs provide the framework for safe and effective care and are to be encouraged.” Muldoon et al (2014). Reference: Muldoon, E.G., Switkowski, K., Tice, A., Snydman, D.R. and Allison, G.M. (2014) A national survey of infectious disease practitioners on their use of outpatient parenteral antimicrobial therapy (OPAT). Scandinavian Journal of Infectious Diseases. November […]

Improvement in drug delivery by pump-driven intravenous infusion

central line occlusion

“This study evaluated computer algorithms for reducing temporal lags via coordinated control of drug and carrier flows.” Parker et al (2014). Reference: Parker, M.J., Lovich, M.A., Tsao, A.C., Wei, A.E., Wakim, M.G., Maslov, M.Y., Tsukada, H. and Peterfreund, R.A. (2014) Computer Control of Drug Delivery by Continuous Intravenous Infusion: Bridging the Gap between Intended and […]

Computer-automated CLABSI surveillance review

CLABSI prevention

“We assessed whether a computer-automated method of central line-associated BSI detection can improve the validity of surveillance.” Lin et al (2014). Reference: Lin, M.Y., Woeltje, K.F., Khan, Y.M., Hota, B., Doherty, J.A., Borlawsky, T.B., Stevenson, K.B., Fridkin, S.K., Weinstein, R.A. and Trick, W.E. (2014) Multicenter Evaluation of Computer Automated versus Traditional Surveillance of Hospital-Acquired Bloodstream Infections. […]

Femoral central venous catheters in severely burned patients

CVC

“The objective of this study is to determine the catheter-related bloodstream infection (CRBSI) rate in a severely burned patient population” Friedman et al (2014). Reference: Friedman, B.C., Mian, M.A., Mullins, R.F., Hassan, Z., Shaver, J.R. and Johnston, K.K. (2014) Five-Lumen Antibiotic-Impregnated Femoral Central Venous Catheters in Severely Burned Patients: An Investigation of Device Utility and […]

Comparison of heparin to citrate as a catheter locking solution

PICC

“We aim to compare citrate 4% catheter lock solution versus heparin in terms of event-free survival of the first non-tunneled hemodialysis catheter inserted in ICU patients” Bruyère et al (2014). Reference: Bruyère, R., Soudry-Faure, A., Capellier, G., Binquet, C., Nadji, A., Torner, S., Blasco, G., Yannaraki, M., Barbar, S.D. and Quenot, J-P. (2014) Comparison of heparin […]

Report on device-associated infection rates in Turkey

clabsi

“We report the results of the International Infection Control Consortium (INICC) study conducted in Turkey from August 2003 through October 2012.” Leblebicioglu et al (2014). Reference: Leblebicioglu, H., Erben, N., Rosenthal, V., Atasay, B., Erbay, A., Unal, S., Senol, G., Willke, A., Ozgültekin, A., Altin, N., Bakir, M., Oncul, O., Ersöz, G., Ozdemir, D., Yalcin, […]

Fluoroscopy-guided umbilical venous catheter placement

central venous

“The objective of this study was to (1) describe the technical aspects of fluoroscopy-guided umbilical venous catheter placement (FGUVCP); and (2) determine the procedural success rate, factors contributing to procedural failure, and risks of the procedure.” DeWitt et al (2014). Reference: DeWitt, A.G., Zampi, J.D., Donohue, J.E., Yu, S. and Lloyd, T.R. (2014) Fluoroscopy-guided Umbilical […]

Efficacy and safety of early use of urokinase for fibrin sheath treatment

needlestick

“…clinical efficacy and safety of the early use of urokinase in the prevention and treatment on tunneled hemodialysis catheter related fibrin sheaths” Li et al (2014). Reference: Li, X.T., Liu, D., Wang, Y.B., Wang, M., Zhang, J. and Guo, Y. (2014) Efficacy and safety of early use of urokinase for prevention and treatment of tunneled […]

Review of invasive procedures for terminally ill cancer patients

infusion

“Although more palliative care is necessary for terminally ill cancer patients, excess investigational tests, invasive procedures, and treatments are given instead.” Türker et al (2014). Reference: Türker, I., Kömürcü, S., Arıcan, A., Doruk, H., Ozyılkan, O., Coşkun, H.S., Colak, D., Uçgül Çavuşoğlu, E., Ata, A., Sezer, A., Yeşil Çınkır, H., Senler, F.C. and Arpacı, F. […]

Safety and efficacy of rapid rituximab infusion plus chemotherapy

intravenous

“…evaluate the safety and efficacy of rapid rituximab infusion (RRI) plus chemotherapy in patients with CD20+ non-Hodgkin’s lymphoma” Zhao et al (2014). Reference: Zhao, W., Gao, Y., Bai, B., Cai, Q.C., Wang, X.X., Cai, Q.Q. and Huang, H.Q. (2014) Safety and efficacy of noninitial rapid infusion of rituximab plus chemotherapy in Chinese patients with CD20+ […]

Live cadavers contribute to vascular access training

vascular access study

“Simulators for vascular access range over a wide spectrum from simple systems to sophisticated computer simulators, all of these model proved efficacy, but non of them truly represent the real human anatomy accompanied with the real life-like situation at the same time.” Aboud (2014) Reference: Aboud, E. (2014) Live Cadavers, a New Model for Vascular […]

Ethanol lock for reduction of central line-associated bloodstream infection

infusion reaction

“This case study reviews the use of ethanol lock therapy for a pediatric patient who experienced 0 central line-associated bloodstream infections during the 2-year time period covered by this report.” Pitts et al (2014). Reference: Pitts, S., Bergamo, D., Cartaya, C. and Gore, B. (2014) Efficacy in the Reduction of Central Line-Associated Bloodstream Infection in […]

Evidence-based guidelines for CVAD insertion, management and removal

picc dressing

“Our aim was to adapt recommendations from high-quality, evidence-based clinical practice guidelines (CPGs) for central vascular access device (CVAD) insertion, management, and removal in King Saud University Medical City.” Ciocson et al (2014). Reference: Ciocson, M.A.F.R, Hernandez, M.G., Atallah, M. and Amer, Y.S. (2014) Central Vascular Access Device: An Adapted Evidence-Based Clinical Practice Guideline. The […]

Vascular access device management algorithm described

vancomycin lock

“Due to safety and regulatory compliance, the use of a “standing orders” protocol was prohibited. This issue led to the process of obtaining physician orders and awaiting responses for procedures needed.” Guerrero (2014). Reference: Guerrero, S. (2014) Vascular Access Devices Management Algorithm Process Development. The Journal of the Association for Vascular Access. 19(4), p.210. [ctt […]

Central venous catheter tip termination identification

picc tip

“The advances in central catheter placement technology have presented clinicians and their facilities opportunities to aggressively challenge the gold standard paradigm of utilizing chest radiography for central catheter tip termination identification.” Owens (2014). Reference: Owens, A.K. (2014) CAJ without CXR: One Small Hospital’s Journey to Change the Paradigm in Peripherally Inserted Central Catheter Tip Termination […]

Advantages of transparent IV dressings over tape and gauze

CVC

“Our goal was to review the current literature and provide an overview of the various approaches used to manage PIV catheter sites as well as review current recommendations.” Bernatchez (2014). Reference: Bernatchez, S.F. (2014) Care of Peripheral Venous Catheter Sites: Advantages of Transparent Film Dressings Over Tape and Gauze. The Journal of the Association for […]

ECG tip location algorithm for atrial fibrillation patients

shock

“The intracavitary electrocardiographic method (IC-ECG) is usually considered not applicable when P wave is not evident on basal ECG, such as in atrial fibrillation (AF) or in active pace-makers (APM).” Pittiruti et al (2014). Reference: Pittiruti, M., LaGreca, A., Emoli, A., Calabrese, M., Biasucci, D.G. and Scoppettuolo, G. (2014) Tip Location of Central Venous Access […]

Neonatal vascular access provision reviewed and refined

neonatal picc

“We combined the vascular access team (VAT) and NICU PICC team to improve the timeliness of NICU PICC insertions, standardize care, and use ultrasound for all PICC placements.” deCastro et al (2014). Reference: deCastro, M.V.A., Eades, L.J., Rineair, S.A. and Schoettker, P.J. (2014) Proactive Planning for Vascular Access Therapy: One Hospital’s Plan for Success. The […]

NICU collaboration reduces PICC associated CLABSI

PICC

“In an effort to reduce Central Line (CLABSI) infections in the NICU, collaboration was made between nursing and medical teams to develop a partnership in PICC line insertion.” Marchetti et al (2014). Reference: Marchetti, J., Morey, JA., Blaine, T., Greene, D., Field, M. and McDermott, AM (2014) RN and Physician PICC Team Partnership in the […]

PICC placement and lean-based methodology

intravenous infusion

“The peripherally inserted central catheter implantation and maintenance process was optimized at Shanghai Fu Dan University Cancer Center using lean-based methodology.” Zhu et al (2014). Reference: Zhu, Y., Lu, Z. and Dai, H. (2014) Improving Efficiency and Patient Satisfaction in a Peripherally Inserted Central Catheter Center Using Lean-Based Methodology. The Journal of the Association for […]

Simulation-based education for transfusion medicine

simulation training in transfusion medicine

“Our institution developed a feasible and effective way to integrate TM into the curriculum. Educational activities, such as this, might be a way to improve the safety of transfusions.” Morgan et al (2014). Reference: Morgan, S., Rioux-Masse, B., Oancea, C., Cohn, C., Harmon Jr, J. and Konia, M. (2014) Simulation-based education for transfusion medicine. Transfusion. November […]

80% of all human infections are attributable to microbes in biofilms

clabsi

“…biofilms research is critical because 80% of all human infections are attributable to microbes in biofilms.” Phillips et al (2014). Reference: Phillips, K.S., Patwardhan, D. and Jayan, G. (2014) Biofilms, medical devices, and antibiofilm technology: Key messages from a recent public workshop. American Journal of Infection Control. November 15th. [epub ahead of print]. [ctt tweet=”80% […]

Pharmacokinetics of caspofungin in ICU patients

CVC

“Caspofungin PK in ICU patients showed limited intraindividual and moderate interindividual variability, and caspofungin was well tolerated.” Muilwijk et al (2014) Reference: Muilwijk, E.W., Schouten, J.A., van Leeuwen, H.J., van Zanten, A.R.H., de Lange, D.W., Colbers, A., Verweij, P.E., Burger, D.M., Pickkers, P. and Brüggemann, R.J.M. (2014) Pharmacokinetics of caspofungin in ICU patients. Journal of Antimicrobial […]

Ultrasound-guided subclavian venipuncture training reviewed

cvc ultrasound

“Both ultrasound-guided subclavian venipuncture (US-SV) and landmark-guided subclavian venipuncture (LM-SV) are important in critical care… The aim of this study is to compare learning these two techniques in a simulation environment” Tokumine et al (2014).

International baseline for medication safety in oncology

tip location

“This self-assessment was designed to assist oncology practitioners in hospitals, ambulatory care centers, and office practice settings throughout the world to evaluate safe practices related to medication use in the oncology setting” Greenall et al (2014).

Intravenous fluid administration for resuscitation

intravenous fluids

“The administration of intravenous fluids for resuscitation is the most common intervention in acute medicine. There is increasing evidence that the type of fluid may directly affect patient centred outcomes” Myburgh (2014).

Study characterises risk profile of intravenous immunoglobulin

intravenous drip

“To better characterize the risk profile of the intravenous immunoglobulin (IVIG) Intratect®, a non-interventional study was undertaken to systematically collect large-scale safety information under real-life conditions in patients with primary and secondary immunodeficiency” Bauhofer et al (2014).