Ultrasound-guided CVC simulation workshop

central line

“An ultrasound-guided CVC simulation workshop can appreciably advance anesthesia providers’ technical skills and decrease procedure time when performing insertion of a simulated internal jugular CVC” Rivera et al (2023).

Calcified fibrin sheath embolism case study

IVTEAM Intravenous Literature

“The purpose of this report is to present bilateral pulmonary artery embolism in a patient who presented with cough and chest pain caused by calcified fibrin sheath of the port catheter” Gürhan and Kılınçer (2023).

Vein identification technology

peripheral iv

“New, evidence-based technologies can improve venous access for phlebotomy and I.V. insertion, especially in patients with difficult I.V. access” Kaganovskaya et al (2023).

Malposition of totally implantable venous access port – Full Text

iv port

“The catheter malposition rate of ultrasound-guided TIVAP implantation via IJV is low, and the malposed catheter can be successfully adjusted to the proper position by simple manipulative repositioning or DSA-assisted percutaneous positioning, however, the catheter malposition incidence of TIVAP implanted via left IJV is higher than that via the right side” Liu et al (2023).

Stepdown from IV to oral antibiotics

drug aministration

“The purpose of this study was to compare the clinical outcomes of adults with uncomplicated streptococcal bacteremia who received either oral stepdown (PO) or continued intravenous (IV) therapy” Waked et al (2023).

Extended dwell peripheral IV catheters in neonates

peripheral iv

“EPIV catheters may be an appropriate alternative device to PIV catheters due to fewer placement attempts, longer dwell times, and overall fewer complications during use” Marchetti et al (2023).

OPAT for prosthetic joint infections

IVTEAM Intravenous Literature

“Treatment includes surgical intervention with prolonged courses of IV antibiotics in outpatient parenteral antimicrobial therapy (OPAT) programs. The risk of PJI treatment failure is high and may be associated with various clinical factors” Flaten et al (2023).

Ultrasound-guided CVC options

ultrasound guided vascular access

“No difference was found between the real-time ultrasound-guided out-of-plane cannulation of the IJV and the infraclavicular real-time ultrasound-guided in-plane cannulation of the AXV” Czarnik et al (2023).

Needlestick injury prevalence in healthcare students – Full Text

needlestick

“The present study found that one in four students experience needlestick injury; overall knowledge regarding prevention and management of needlestick injury was lesser than desired, and gaps in knowledge and practice were identified in the present study” Datar et al (2022).

Central line fracture example – Full Text

central line

“Here, we report a case of right internal jugular triple-lumen central venous catheter fracture and subsequent embolism to the right pulmonary artery” Towheed et al (2022).

Medical student IV cannulation skills – Full Text

peripheral iv

“A single, short refresher seems to have a limited effect on intravenous-cannulation skills in first-year medical students. Less resource-intensive interventions, such as written instructions or mental imagery, are effective compared with hands-on part-task trainer simulation for refreshing this simple but important skill” Berger-Estilita et al (2022).

Multi-infusion therapy accuracy – Full Text

Drug administration

“Using the predictive tool to visualise the deviations from the set flow rate is an effective method to allow clinicians to gain insight in dosing errors in multi-infusion therapy” Gevers et al (2023).

Low flow infusion pump accuracy

Infusion pump

“The occlusion alarm may be much delayed and not useful in highly compliant systems with respect to the potential occlusion of the infusion system, so more attention is required when using a highly compliant infusion system” Hong et al (2023).

Pleural effusion after PICC insertion – Full Text

picc

“When pleural effusions quickly accumulate after placement of a peripherally inserted central catheter despite using confirmatory image guidance, delayed complications must be thought of, and offending medications and catheter should be removed in a timely fashion to avoid further morbidity and mortality” Yang and Lopez (2023).