Repeated blood collection using needlefree connectors – Full Text

“Needle-free blood collection devices that access peripheral intravenous (IV) catheters may provide an alternative approach to repeated venipuncture while maintaining sampling schedules and specimen quality” Naviaux et al (2026).
Review of needleless connector designs – Full Text

“Split septum demonstrated a trend in lower incidence of CLABSI. This result should be weighed carefully in determining the needleless connector type best suited for very preterm or VLBW neonates” Marsubrin et al (2026).
Needleless connector care – Full Text

“This article provides a review of the critical role of the nurse in identifying risks and applying best practices in NC care, including disinfection, clamping, flushing, and timely replacement” Moureau and Gorski (2026).
Needle-free connectors in tunneled central venous catheters for hemodialysis – Full Text

“n this short-term single-centre cohort, high-flow split-septum needle-free connectors appeared feasible and microbiologically safe on hemodialysis t-CVCs, without compromising dialysis delivery or routine catheter care” Leskovar et al (2026).
Needlefree connector design and function

“This article provides an explanation of NFD design and functions, guidance and information about their benefits when used correctly, as well as advice on preventing possible complications associated with their use” Munoz-Mozas (2025).
Disinfectant agents for needleless connector decontamination – Full Text

“Effective NC disinfection before catheter use is therefore critical. This study evaluated the efficacy of three disinfectant agents across varying decontamination durations and drying times” Kuek et al (2025).
Needle-free connector evaluation

“This study examined the performance of various NFC technologies with PICC and Midline. While no device eliminates BV, positive displacement NFCs showed lower flow reflux compared to the others when used with PICC. No difference between clamping sequences was observed for neutral and anti-reflux NFCs” Privitera et al (2025).
Impact of needleless connectors on long peripheral IV catheters

“Using only needleless connectors in long peripheral catheters does not prevent the backflow phenomenon. Using clamps significantly reduced the backflow volume in needleless connectors with positive and negative displacement. Neutral and anti-reflux connectors perform similarly in the clamping sequences with and without clamps” Giustivi et al (2025).
Antimicrobial coated needle-free connector

“>Needle-Free connectors (NFCs) are widely used to access vascular infusion circuits. Despite their safety benefits, NFCs still present risks for colonization and vascular ingress by pathogenic microbes” Truong et al (2025).
Needleless connector systematic review – Full Text

“A systematic review of the literature was performed to ascertain whether the functional design of anti-reflux NCs results in reduced catheter occlusion” Moureau et al (2025).
Preventing backflow and occlusion of short-term dialysis catheters

“The aim of this study was to evaluate the backflow associated with two NFCs (Neutron™ and Tego™) compared to the standard closure” Privitera et al (2024).
Needleless connector technology as a CLABSI risk reduction strategy – Full Text

“The use of the Clave NCT, in and of itself, is an effective risk reduction strategy for CLABSI prevention, reduced mortality, and substantial cost savings” Ryder and Battle (2024).
Disinfection of needleless connectors with ultraviolet light – Full Text

“We demonstrated the efficacy of UV-C for the disinfection of NCs in one second using the UV-C device in benchtop studies” Fourkas et al (2024).
Needleless connector flow rates

“In this study we utilised a rapid infuser to deliver room-temperature normal saline through two introducer sheath configurations with and without the addition of needleless connectors and the placement of catheters through the introducer sheaths” Smeltz et al (2024).
Needleless connector disinfection competency

“The goal of this study was to observe needleless-connector disinfection practices and to identify perceived facilitators and barriers to best practices of needleless-connector access” Drews et al (2024).
Isopropanol leakage from antiseptic barrier caps

“Needleless connectors (NCs) can be disinfected using antiseptic barrier caps (ABCs) to reduce the risk of catheter-related bloodstream infections. However, recent evidence suggests that isopropanol can leak from the ABC into the NC, posing concern about their safe use” Boissière et al (2024).
Needleless connector disinfection procedure – Full Text

“This study aimed to verify the efficacy of disinfection procedures to reduce Acinetobacter baumannii blaOXA-23 bacterial load in needleless connectors that had been experimentally contaminated” Biazus-Dalcin et al (2024).
5-FU contamination and closed-system transfer device

“Occupational exposure to cytotoxic drugs can lead to significant health problems. This study was designed to evaluate the risk of 5-fluorouracil (5-FU) contamination for nurses when disconnecting the infusion line of an elastomeric pump from a non-coring needle” Raphaëlle et al (2023).
Closed system transfer device review

“The aim of the present article is to review of medical devices used for safe chemotherapy applications in line with the information obtained from the literature” Tekin et al (2023).
Needleless connector design and PIVC failure

“The neutral NC was associated with an increased risk of peripheral intravenous catheter failure” Marsh et al (2023).
Products for disinfecting needleless connectors

“Comparing three different products for disinfecting needleless connectors showed that all were more effective than sterile water, but nurses preferred using chlorhexidine gluconate with isopropyl alcohol wipes” Rosenberg (2023).
Needleless connector microbial contamination

“The aim of this study was to determine bacterial contamination of needleless connectors before and after disinfection to assess the risk for the point of catheter-related bloodstream infections” Akbıyık et al (2023).
Bacterial transfer and biofilm formation in needleless connectors – Full Text

“Bacterial transfer and biofilm formation in the connector-catheter system varied statistically significantly between the 20 NCs, suggesting that NC choice can lower the risk of developing catheter-related BSIs” Ryder et al (2023).
Positive and neutral needleless connector study

“A pragmatic, multiphase prospective quality improvement initiative was performed to determine whether a positive displacement connector (PD) causes reduction of central line-associated bloodstream infection (CLABSI), occlusion, and catheter hub colonization when compared with a neutral displacement connector with alcohol disinfecting cap (AC)” Schora et al (2023).
Needleless connector contamination before and after disinfection

“The majority of needleless connectors had bacterial contamination before disinfection. Needleless connectors should be disinfected for 30 seconds before use, particularly in immunocompromised patients” Akbıyık et al (2023).
Disinfection of needleless connectors

“This study aimed to gain further knowledge about the comparative effectiveness of chemical disinfectants in reducing the bacterial load of NCs inoculated with S. aureus” Rocha et al (2022).
Needleless connector decontamination

“The findings indicated the need for targeted, standardised needleless connector education, to enhance staff confidence, improve consistency of care and ensure patient safety” Larsen et al (2022).