Measuring venous oxygen saturation from midline catheters

midline catheter

“Midline catheters are inserted via a peripheral vein above the antecubital fossa and provide a safe alternative to CVCs. This study aimed to determine the equivalence of ScvO2 and midline catheter oxygen saturation (SmO2) in critically ill patients” Kim et al (2024).

Midline catheter use in the neonatal intensive care unit

midline catheter

“The midline catheter has advantages over short peripheral catheters, being a useful alternative in terms of efficacy and safety for treatments lasting more than 3 days in the neonatal population that requires admission to the NICU” Sánchez García et al (2024).

Midline catheter use in pediatric apheresis

midline catheter

“In conclusion, this study supports the use of midline catheters as a safe and effective alternative for venous access during therapeutic and donor apheresis procedures in pediatric patients” Geile et al (2024).

Midline catheters in managing septic shock – Full Text

midline catheter

“Despite the heterogeneity, midline catheters are categorically more reliable than peripheral IVs with reported average dwell times of 16.3 days for midline catheters versus 4.8 days for peripheral IVs” Bracey and Sherman (2024).

Midline catheters in neonatal intensive care

midline catheter

“The purpose of this article is to present the advantages and disadvantages of MPCs as an alternative approach for venous access in neonates when appropriate” Sykes et al (2024).

Midline catheter peripheral blood stem cell collection

midline catheter

“Peripheral blood stem cell collection does appear to be viable via midline-based catheter access, particularly for allogeneic donors and shorter collection courses. Development of institution-specific guidelines and care pathways are recommended” Tran et al (2024).

Taking blood samples from midline catheters

midline catheter

“The study concluded that blood draws from midline catheters are clinically equivalent to venipuncture and are an acceptable form of specimen collection for laboratory studies” Minor and Pfeiffer (2024).

Midline catheter tip locations

midline catheter

“Placement of the midline catheter tip in the subclavian vein was superior to that in the axillary vein in terms of complication rates and the incidence of catheter-related thrombosis. Whether different midline catheter tip locations lead to differences in the catheter indwelling time or the rates of other complications remains unclear” Zhang et al (2023).

Midline catheter in pediatric patients

midline catheter

“Findings suggest that MC insertion for patients requiring peripherally compatible intravenous therapy for 4 days or longer should be prioritized to reduce the resource intensive, expensive, and burdensome sequelae of device failure” Kleidon et al (2023).

Midline catheter-related thrombosis risk factors

midline catheter

“This study found that catheter-to-vein ratio >0.40, distance from the antecubital fossa >7 cm, and body temperature ≥38°C were each associated with higher risk of MCRT” Bahl et al (2023).

Risk of midline catheter-related thrombosis

midline catheter

“Smaller diameter catheters should be preferentially chosen to mitigate the risk of thrombosis when therapy via midline catheters is required. Choosing a catheter based on reduced size or 1:3 catheter to vein ratio threshold has similar accuracy in predicting DVT” Bahl et al (2023).

Vasopressor administration through a midline catheter

midline catheter

“We found no significant association of vasopressor administration though a midline with catheter-related complications. However, we identified an increased odds of systemic (but not ipsilateral upper extremity) venous thromboembolism warranting further evaluation” Gershengorn et al (2023).

Midline catheter and PICC comparison

midline catheter

“Our aim was to assess feasibility and generate clinical data comparing MCs with Peripherally Inserted Central Catheters (PICCs)” Marsh et al (2023).

Midline insertion service implementation

midline catheter

“Despite limited resources, a successful midline service was introduced. Future expansion will see an increase in insertor numbers providing improved access to the service” Jones (2023).

Blood sampling from midline catheters

midline catheter

“In stabilized critical patients, midline catheters represent a reliable alternative to CVC and arterial lines to monitor acid-base disturbances, CO2 levels and electrolytes” Giani et al (2023).

Midline catheter for high-risk medications

midline catheter

“Due to the low rates of extravasation in midline catheters found in this study, midline catheters may serve as viable alternatives to central venous catheters for the infusion of vasopressor medications and should be considered by practitioners as a route of infusion in critically ill patients” Matthew (2022).

Pediatric midline catheter complications

midline catheter

“In children, thrombotic and mechanical complications of midline catheters are common, but only few VTEs are severe enough to warrant anticoagulation therapy” Östlund et al (2022).

Midline catheter complications

midline catheter

“The most common causes of midline catheter failure were infiltration/extravasation, accidental removal, and catheter-related thrombosis” Tran et al (2023).

Midline catheter vs peripheral IV – Full Text

midline catheter

“It aims to compare the complications associated with intravenous therapy between the control group (CG) with a PIVC and the experimental group (EG) with a midline in an Internal Medicine Unit of a Spanish hospital for three months” Villalba-Nicolau et al (2022).