Infusion devices for subcutaneous immunoglobulin therapy – Full Text

“Mechanical infusion systems were associated with consistently lower reported rates of local infusion-site reactions compared with electronic infusion systems in this descriptive synthesis, while both system types effectively achieved IgG levels consistent with adequate dose delivery” Majapuro-Hirvonen et al (2026).
IV pump availability linked to hospital bed numbers

“Pump ownership was strongly correlated with the number of beds for both infusion and syringe pumps. Pumps per bed ranged from 0.26 to 0.48 for infusion pumps and from 0.16 to 0.45 for syringe pumps” Imada et al (2026).
Targeted infusion pump calibration method

“Establishing a measurement and acceptance system based on nursing needs can effectively eliminate the risks of clinical use of infusion pumps and has important practical significance for improving the level of nursing safety management” Li et al (2026).
Management of home medical equipment – Full Text

“This study aims to elucidate the relationship between equipment malfunctions and management practices at visiting nursing stations (stations), as well as to assess the perceived need for CEs” Hamasaka et al (2026).
Intravenous chemotherapy administration using smart infusion pumps

“A clinical pharmacist-led parameterised smart pump programme strengthened standardisation at the point of administration and supported a proactive medication-safety culture in routine practice” Ioannidis et al (2026).
Reducing intravenous smart pump alert override rates

“This study expands on the IVSP alert data published to date and highlights 3 key measures of alert override rates, including alert salience. Understanding the frequency and types of IVSP alerts and alert responses is critical for reducing unnecessary IVSP alerts and reducing alert fatigue” Armistead et al (2026).
Integration of smart infusion pumps with electronic medical records – Full Text

“Smart pump-EMR integration and autoprogramming were associated with significantly fewer safety alerts, fewer steps to initiate infusions, and shorter times to resolve alerts” Afaq et al (2026).
Review of intravenous smart pump alarms – Full Text

“Downstream occlusion, air-in-line, infusion-complete, and upstream occlusion alarms dominated the 2 years of alarm data, generating the majority of the 5 million IVSP alarms” Nyarko et al (2026).
Vasoactive drug syringe infusion pump changeover – Full Text

“This review highlights the need for evidence-based guidelines for syringe pump changeover methods. Standardized procedures and optimized protocols for automated/smart syringe pumps can minimize errors, improve drug delivery accuracy, and enhance critical care quality” Li et al (2026).
Monitoring smart infusion pumps in adult intensive care units – Full Text

“The results were consistent with other studies, demonstrating drug library compliance ranging from 65% to 80% during the first year of implementation” Narváez-Martínez et al (2026).
IV Pump position during vasoactive drug delivery

“Residual syringe air and infusion pump vertical position are critical, interacting factors that disrupt flow continuity during vasoactive drug delivery” Chang et al (2026).
Drug library for continuous infusions in a paediatric intensive care unit

“This scalable model demonstrates how smart pumps, EMR integration and multidisciplinary training can significantly reduce continuous infusion errors in PICUs, enhancing safety for vulnerable paediatric patients and providing a framework for adoption in other high-risk settings like emergency departments and subspecialty wards” Osman et al (2026).
Simulation-based infusion pump testing – Full Text

“The study results can provide a basis for the design of infusion pumps, help practitioners define the risks of use and the key content of training, and provide an important reference for the design of usability evaluation schemes for medical devices” Wan et al (2026).
Over 65 million infusion pump alarms analyzed

“Over 65 million alarms were analyzed. Infusions of antibacterials generated a higher percentage of “Door Open” and “Bolus Air in Line” alarms than were generated in the all-infusion sample” Armistead et al (2026).
Interruptions during IV smart pump medication administration – Full Text

“The objective of this project was to contribute to the understanding of how interruptions impact intravenous (IV) medication processes and identify areas for improvement” Vital et al (2026).
Customized infusion pump tubing

“A large healthcare system launched a quality improvement initiative to reduce pump alarms and minimize residual volume by implementing customized tubing solutions” Pouliot et al (2026).
How to manage air in line alarm

“Infusion pumps are designed to alarm when air in the IV line (AIL) reaches a set threshold and can result in disruptions in drug delivery and decreased nursing productivity. Depending on the method employed, removal of AIL can also pose a risk to healthcare workers and patients” Eisenberg and Trick (2026).
Elastomeric infusion pumps for in-patient IV antibiotic administration – Full Text

“This study aimed to assess the feasibility of giving IV antibiotics using EMPs to adult inpatients and to identify barriers and facilitators for their implementation” Spencer-Jones et al (2025).
Infusion pump cybersecurity issues

“We present a DDoS attack that alters the pump’s operation, potentially leading to over-infusion or under-infusion of medication. We then assess the implications of these security flaws on patient safety and device reliability” Lu et al (2025).
IV smart pump infusion and alarm evaluation

“This study provides valuable insights into the prevalence and characteristics of IVSP infusions and alarms. Key patterns in alarm frequency and alarm type and association between alarms and key infusion characteristics are also highlighted” Armistead et al (2025).
Intravenous smart pump alarm fatigue

“A systems-level approach combining human factors engineering, intelligent algorithm development, and clinical partnerships with manufacturers is essential for reducing alarm-related risk, decreasing nursing workload, and improving patient outcomes” Nyarko and Giuliano (2025).
Intravenous smart pump usability in acute and critical care

“Although these technologies offer improvements over manual administration, IV smart pumps are associated with high rates of medication errors, programming challenges, and usability issues” Giuliano et al (2025).
Economic impact of smart infusion pump implementation – Full Text

“The implementation of smart infusion pump interoperability has the potential to enhance patient safety by reducing pADEs and improving outpatient administration charge capture” Borrelli et al (2025).
Infusion pump operation during flight

“An in vitro study of six volumetric pumps and eight syringe drivers was conducted in a hypobaric chamber to mimic pressure changes during flights” Fan et al (2025).
Infusion pump comparison during perioperative cardiac surgery simulation

“This study compares 2 commercially available infusion pumps in a simulated cardiac surgical perioperative setting to assess differences in usability, medication errors, and programming workload among experienced and trainee healthcare professionals” Greenberg et al (2025).
Intravenous smart pump review

“The first programmable infusion pumps were invented over 50 years ago, but their adoption in hospitals was slow, and their initial functions were limited to basic programming in milliliters per hour” Blake et al (2025).
Portable infusion pump evaluation – Full Text

“The electronic pumps maintained consistent flow rates across various conditions, whereas elastomeric balloon pumps exhibited variable rates influenced by time and temperature, increasing the risk of medication overdose. Bolus dosing accuracy was clinically satisfactory for all pump mechanisms” Sekiguchi et al (2025).
Smart infusion device research – Full Text

“The smart infusion automatic medication replacement device enhances the quality of infusion therapy for patients and alleviates the repetitive workload of medical staff” Mu et al (2025).
Artificial intelligence and infusion pumps – Full Text

“It has been established that machine learning methods are capable of identifying potential issues before they become critical, thus playing a crucial role in predicting the performance of infusion pumps, potentially enhancing the safety, reliability, and efficiency of healthcare delivery” Merdović et al (2025).
Human factors engineering considerations for infusion pump procurement – Full Text