Salvage totally implantable ports with antibiotic lock therapy – Full Text

iv lock

“TIP salvage was associated with the infecting organism. The pathogen gradient mirrored guideline-based removal recommendations. About 60% of attempted retentions succeeded, without detectable benefit of ALT. With a pathogen-stratified protocol, salvage can be attempted in selected patients” Rothe et al (2026).

IV catheter lock study

iv lock

“Participants were randomized 1:1 to receive systemic antibiotics plus minocycline-EDTA-ethanol lock therapy (MLT) or standard-of-care antibiotic lock therapy (SOC-ALT) for 7 to 14 days” Chaftari et al (2026).

Gentamicin lock therapy and duration

iv lock

“This study compared catheter-related bloodstream infection (CRBSI) outcomes and duration-modifying effects between gentamicin-heparin and heparin-only lock protocols” Tsai et al (20260.

Impact of catheter design on hemodialysis catheter lock therapy

iv lock

“This review argues that the biological effect ultimately achieved within the catheter may also be shaped by catheter architecture and lock-handling variables, including tip design, side-hole geometry, true luminal volume, fill ratio, lock density, interdialytic dwell, and aspiration practice” Corrêa et al (2026).

Antibiofilm efficacy of stabilised hypochlorous acid

iv lock

“Stabilised HOCl demonstrated substantial antibiofilm activity while preserving cellular morphology under the conditions tested. These findings suggest that HOCl may represent a promising candidate for catheter-related infection prevention, although further studies incorporating functional cytotoxicity assays are required” Daştan et al (2026).

Antimicrobial lock solution dwell time – Full Text

iv lock

“Optimal ALS dwell time depends on the antimicrobial agent. Vancomycin and linezolid locks require daily replacement, whereas daptomycin, tigecycline, and teicoplanin locks maintain therapeutic concentrations for up to 7 days” Bustos et al (2026).

Ethanol lock therapy for salvage of infected CVC – Full Text

iv lock

“Tunnelled catheter-related bloodstream infections (CRBSIs) in haemodialysis (HD) are challenging to manage due to biofilm formation. Ethanol lock therapy (ELT) has demonstrated potential as an adjunct to antibiotics for catheter salvage, but robust evidence is limited” Prasad et al (2026).

IV lock in pediatric intestinal failure patients – Full Text

iv lock

“These findings contribute to the characterization of the microbiological profile of CRBSIs in pediatric patients with IF and support the use of advanced preventive strategies, such as taurolidine lock therapy, to reduce infection rates in children receiving long-term PN” Vicentin de Souza et al (2026).

Hydrochloric acid lock therapy for CRBSI – Full Text

iv lock

“This study evaluated the efficacy of hydrochloric acid (HCl) against biofilms of Staphylococcus aureus, Pseudomonas aeruginosa, and Staphylococcus epidermidis, and assessed its effects on silicone and polyurethane central venous catheters” Mønster et al (2026).

Efficacy of IV catheter lock solutions

iv lock

“his systematic review and Bayesian network meta-analysis synthesized available evidence by comparing different CLs directly and indirectly to prevent CLABSI and rank their effectiveness” Liu et al (2026).

Comparison of IV catheter lock solutions – Full Text

iv lock

“Taurolidine and EDTA locks are similarly effective in preventing infections and equally likely to be associated with occlusion or breakage. Both are suitable for children with IF on long-term PN” Ahisar et al (2026).

Antimicrobial locks for CLABSI prevention

clabsi

“This review highlights the need for well-designed studies to determine the clinical effectiveness of antimicrobial locks for primary and secondary CLABSI prevention in specific pediatric populations and to determine whether there is differential impact by lock type” L’Etoile et al (2026).

IV lock frequency for preventing catheter dysfunction – Full Text

iv lock

“The study aims to identify a relatively low-risk locking frequency for catheter dysfunction, evaluate its effects on maintaining catheter patency and preventing catheter-related bloodstream infections (CRBSI), and determine the optimal locking strategy that balances infection risk and catheter functionality” Zhang et al (2026).

Meropenem-heparin lock therapy for CRBSI treatment – Full Text

iv lock

“Ochrobactrum intermedium was isolated from all catheter lumens and blood cultures. Due to a documented history of vascular access failure, catheter salvage was the primary goal. A combined systemic antibiotic and lock therapy with meropenem and unfractionated heparin was initiated” Rodrigues et al (2026).

Efficiency of taurolidine lock solution – Full Text

iv lock

“Standardized TCS lock therapy effectively and safely reduces CRBSIs in pediatric patients with IF, particularly those caused by Gram-negative and fungal organisms. These results support the use of TCS as a prophylactic option for preventing infection in long-term CVC use” Aksoy et al (2025).

Blood sampling discard volume from PICC

iv lock

“To evaluate whether discarding 1 mL is sufficient for reliable laboratory testing after use of 4% tetrasodium EDTA catheter lock solution (Kitelock™) in PICC” Rajdl et al (2025).