Impact of in-line IV filters on CLABSI rates – Full Text

“In-line filters were associated with reduced CRBSI, indicating potential benefit in preventing infusion-related contamination” Kato et al (2026).
The role of Pall Medical in-line IV filters

“The case study discusses the use of 1.2 µm in-line filters for the administration of parenteral nutrition in paediatric care to reduce complications and ensure safe infusion practice. The second case study details the integration of the Pall Medical 0.2 µm Supor AEF low protein binding IV in-line filter for the administration of monoclonal antibodies in an outpatient infusion centre setting” Barton and Melville (2026).
Health risks from microplastics in intravenous infusions – Full Text

“The rising incidence of microplastics (MPs) is a possible health risk to humans. The present study aims to analyze the presence of MPs in intravenous (IV) infusions and compare MP concentrations from multiple brands” Casella et al (2025).
Microplastics in intravenous admixtures

“This study investigates MPs in intravenous (IV) admixtures, which are stored in plastic containers before administration. The hypothesis suggests that prolonged storage may degrade container walls, leading to the release of MPs into the solutions” Pal and Chakraborty (2025).
Detection of infusion-related microplastics

“This work examined the content, type, shape, and size of M/NPs released directly into the bloodstream from medical devices via saline solution during intravenous (IV) injection” Mou et al (2024).
Review of plastic particles in medical injections

“Microplastics (MPs) mainly enter the human body through ingestion and breathing. Most of them are excreted through feces, and only a small amount can accumulate in human organs and tissues. In contrast, if intravenous injection contains MPs, it could directly enter bloodstream and maybe pose severe health risk” Liu et al (2024).
Effect of in-line filtration in newborns – Full Text

“If the use of in-line filters results in a significant decrease in sepsis-like events and/or in any other complications, the use of in-line filters in all intravenous administration systems may be recommended in NICUs” Cresi et al (2024).
Microparticle release during continuous renal replacement therapy – Full Text

“Particle infusion and related damage must be counted among the pathophysiological mechanisms supporting iatrogenic damage due to artificial cross-talk between organs during CRRT applied to critically ill patients. This damage can be reduced by using in-line filters in the extracorporeal circuit” Ruffa et al (2024).
Microplastics from neonatal parenteral nutrition circuit – Full Text

“The leaching of particles from plastic health care equipment in the blood of intensive care patients has been associated with several health risks, and as such, similar health risks could occur with leaching of microplastics” Vercauteren et al (2024).
Infusion particles associated with IV pump or gravity infusions – Full Text

“To investigate the impact of an infusion system on the level of subvisible particles, we compared two types of infusion set based on peristaltic movement (Medifusion DI-2000 pump) and a gravity-based infusion system (Accu-Drip) using intravenous immunoglobulin (IVIG) as a model drug” Hada et al (2023).
IV filter replacement interval recommendation – Full Text

“Our study revealed differences in bacterial removal and flow rate under high inoculation among each of three tested in-line filters. We suggest the continuous use of in-line filters for a maximum of six days, while reductions in flow rate after 48 h of continuous use should be carefully noted” Kato et al (2023)
Air Bubbles in Intravenous Infusion Lines: IV In-Line Filters Address the Issue – Pall blog series – Episode 8

“IV in-line filters address the issue of venous air embolism by removing air bubbles from intravenous infusion lines. Watch this video on how Pall IV in-line Filters remove air bubbles from intravenous infusion lines” PALL (2023).
Dosing errors due to air bubbles in infusion lines – Full Text

“The effect of the presence of an air bubble, inside an infusion line, on the time (Tnew) needed for a new medication to reach the patient after a syringe exchange was studied in this paper” Konings et al (2022).
IV filter recommendations differ between clinical societies – Pall blog series – Episode 7

“Over the last years, several societies, mainly parenteral nutrition societies, made recommendations regarding the use of IV in-line filters” Pall (2022).
Why IV In-Line Filters are Vital – A Case Report of a 13-Year-Old Girl – Pall blog series – Episode 6

“…published a case report emphasizing the importance of proper infusion management, including the presence of an Intravenous (IV) in-line filter in the infusion set-up” PALL 2022.
Inside an IV in-line filter – learn more about IV filtration mechanisms – Pall blog series – Episode 5

“Experimental and clinical studies have proven that our IV in-line filtration devices can retain particles, air bubbles, microorganisms, their associated endotoxins, and enlarged lipid droplets” Pall (2022).
Amiodarone infusion associated phlebitis – Full Text

“Central venous catheterization for a high concentration of amiodarone infusion is recommended” Cheewatanakornkul et al (2022).
Watch how IV in-line filters retain particles – Pall blog series – episode 4

“We make the invisible visible and challenged our Posidyne® IV in-line filters with 100 µm polystyrene red labeled particles” Pall 2022.