Laser therapy for iron extravasation-induced skin pigmentation – Full Text

extravasation

“Gradual pigment reduction was observed throughout the treatment course, with complete resolution of hyperpigmentation achieved two years after the first treatment session. Q-switched Nd:YAG laser therapy at 532 nm is an effective treatment for cutaneous siderosis resulting from iron infusion extravasation” Vitale et al (2025).

Tunnelled PICC versus traditional PICC placement – Full Text

picc

“In recent years, the echo-dynamic ultrasound-guided (EDUG) tunneled PICC, a modified technique, has been increasingly adopted in clinical practice. This study aims to compare the safety and efficacy of EDUG-guided tunneled PICC with traditional PICC in cancer patients” Zeng et al (2025).

Analysis of subclavian venous catheterization – Full Text

vascular access

“It was concluded that other catheterization methods (jugular, femoral) are more frequently preferred during anesthesiology residency training. Encouraging trainees to perform subclavian catheterization under ultrasound guidance could be more beneficial in managing critically ill patients during the specialization process” Yalçınkaya et al (2025).

Movement of PICC in relation to limb movement in neonates

picc

“We conducted a prospective observational study to understand PICC movement in relation to limb position in real time. Neonates admitted to a tertiary neonatal unit, at St George’s Hospital, London, needing point of care ultrasound (POCUS) to confirm optimal PICC position were included” Gronska et al (2025).

PICC site bleeding associated with catheter placement in ICU patients

picc

“The modified two-stage technique appears to be a feasible alternative to conventional PICC placement and was associated with reduced insertion-related bleeding in ICU patients. The technique also resulted in fewer dressing changes within 24 h, suggesting more stable haemostasis and potential improvements in ICU care quality” Young et al (2025).

SVC recanalization during implantable port placement – Full Text

iv port

“A patient with a history of cystic fibrosis and bilateral lung transplant presented internal jugular port placement for extracorporeal photopheresis in the setting of acute rejection. Imaging demonstrated chronic calcific stenosis of the right brachiocephalic vein and superior vena cava (SVC)” DePalma et al (2025).

Case study on central line infection in a haematology-oncology patient

clabsi

“We identified a commercially available ‘synbiotic spray’, containing Bacillus strains as the likely source of contamination. We advocate for public health warnings regarding using household probiotic cleaning products in environments with immunocompromized individuals” Messiaen et al (2025).

Short peripheral intravenous catheter maintenance questionnaire

peripheral iv

“The Turkish version of the Questionnaire on Best Practices for Short Peripheral Intravenous Catheter Maintenance demonstrated high reliability, as evidenced by its KR-20 value. The use of this questionnaire enables the identification of knowledge gaps among nursing professionals regarding best practices in short peripheral catheter care” Özbay et al (2025).

Safety of femorally inserted central catheters

vascular access

“When inserted using modern protocols and technologies, FICCs offer a safe and effective alternative for oncology patients without viable upper-body venous access” Parejo Arrondo et al (2025).

Predicting the risk of PICC CLABSI – Full Text

CLABSI

“The risk prediction models for PICC-CLABSI demonstrated strong predictive performance. Future research should carefully address all elements of PROBAST framework during study design phase” Cao et al (2025).

Pharmacist-led PICC validation

picc

“Pharmacist-led PICCs validation improves patient safety and optimises device use, demonstrating its value and sustainability in clinical practice” Tournayre et al (2025).

Review of paired central and peripheral blood cultures

blood sampling

“CLABSI can be diagnosed by differential time to positivity (DTP), where central venous line (CVL) blood cultures grow 120 minutes faster than peripheral cultures drawn at the same time. Peripheral cultures cause patient discomfort, risk contamination with skin flora, may cause delays in clinical care, and the overall impact is uncertain. We investigated our institution’s paired blood culture practice to assess the utility and clinical impact of peripheral cultures” Prudowsky et al (2025).

Complications of chest port implantation

iv port

“Complications are grouped into incision-, catheter-, and reservoir-related categories. Incision complications include adhesive dermatitis, suture pseudoinfection, wound dehiscence, and erosion. Catheter issues include arrhythmias, central venous stenosis, fracture, fibrin sheath formation, thrombosis, and migration, each with distinct clinical implications. Reservoir complications such as port flipping and extravasation may interrupt therapy and cause tissue injury” Schutt et al (2025).

Evaluation of Line Guard for Pediatric CLABSI prevention

clabsi

“The purpose of this study was to assess whether a line guard, a transparent line-to-line barrier against gross contamination, was effective in contributing to the reduction of pediatric CLABSIs” Lulgjuraj et al (2025).

Vascular access team in a rural community hospital

vascular access team

“This article discusses the implementation of a 24-hour VAT, the barriers and outcomes, and many positive benefits of specialized vascular nurses in a rural community hospital” Jungck et al (2025).

Assessing the risk of vascular access device tampering

vascular access

“The pilot of the assessment and program found successful identification of patients at risk for VAD misuse, and interventions were put in place to decrease risk to the patient and hospital” Eastridge et al (2025).

Testing a novel vascular access device in a rabbit model

vascular access

“The results in this study confirm the feasibility of using a rabbit model for further testing and suggest that repeated arterial cannulation with the novel device may be safe and effective for hemodialysis” Pedrotty et al (2025).