"this position paper, developed consistently with current evidence, recommends discontinuing the use of the term fibrin sheath in favor of the more appropriate term fibroblastic sleeve" Spencer et al (2026).
Study typeConsensus statement
PopulationNot applicable; terminology for tissue around vascular access devices
DeviceVenous access devices (terminology of associated tissue)
OutcomeRecommends replacing 'fibrin sheath' with 'fibroblastic sleeve'

Summary

This position paper looks at the fibrin sheath term, which has long been used for the connective tissue that forms around vascular access devices. The authors state that current pathophysiological evidence shows the name is biologically inaccurate and can cause confusion across specialties, including nephrology, interventional radiology, oncology, critical care and cardiology. It may also lead clinicians to treat the lesion as a type of catheter-related thrombosis. Issued as a joint statement of WoCoVA, IVAS and VAS, the paper recommends discontinuing fibrin sheath in favour of fibroblastic sleeve, which better describes the lesion's composition and structure.

Why this matters for practice

The fibrin sheath term appears in clinical notes, protocols and research across many specialties. If it misdescribes the tissue, teams may be basing assessment and treatment decisions on an inaccurate picture of what is happening around the device.

The authors note that the name may lead people to treat the lesion as a form of catheter-related thrombosis. Services may want to review local guidance, education materials and documentation to see where the older term is used, and consider whether shared language such as fibroblastic sleeve would support clearer communication between vascular access, nephrology, radiology and oncology teams.

Key takeaways

  • Fibrin sheath is described as a biologically inaccurate term.
  • The paper recommends the term fibroblastic sleeve instead.
  • The old name may prompt treatment as catheter-related thrombosis.
  • The statement is joint from WoCoVA, IVAS and VAS.
  • Local guidance and teaching materials may need reviewing.

Study abstract

The connective tissue that develops around vascular access devices has traditionally been referred to as a "fibrin sheath." Although this term has remained entrenched in the vascular access literature and across related clinical specialties including nephrology, interventional radiology, oncology, critical care, and cardiology, contemporary pathophysiological evidence indicates that it lacks biological accuracy and does not adequately reflect the nature of this pathophysiological phenomenon. This inaccuracy creates confusion within the scientific community and may erroneously lead to the consideration of this condition as a specific type of catheter-related thrombosis, and to be treated accordingly. As a joint statement of the World Congress on Vascular Access (WoCoVA), the Italian Vascular Access Society (IVAS), and the Vascular Access Society (VAS), this position paper, developed consistently with current evidence, recommends discontinuing the use of the term fibrin sheath in favor of the more appropriate term fibroblastic sleeve. The latter more precisely describes the lesion's biological composition and morphological structure, for the purposes of better clarity and correct management.

— Spencer et al (2026)

Reference and full text

Spencer TR, Pittiruti M, Pinelli F, et al. Redefining venous access device-associated fibroblastic sleeves: Improving terminological accuracy by replacing the misnomer "fibrin sheath". J Vasc Access. 2026:11297298261504490.

DOI: 10.1177/11297298261504490 · PMID: 43061863

Read the full text (free)

Related on IVTEAM

IVTEAM summaries are for education and do not replace local policy or clinical judgement. Copyright in the original article remains with the authors and publisher.