Search
"The nature of docetaxel and partial catheter rupture caused drug extravasation, leading to delayed skin toxicity. The use of a polyurethane catheter reduces the incidence of catheter rupture; hence, silicon catheters should be avoided" Tian et al (2024).

Chemotherapy extravasation following PICC fracture

Abstract:

Herein, we present a patient who was undergoing chemotherapy for bilateral breast cancer and experienced delayed-onset skin toxicity reactions after rupture of a peripherally inserted central catheter (PICC) in the lower extremities. The objective of this case report is to provide the necessary nursing assessment for the risk awareness of the PICC internal rupture and the occurrence of central venous catheter extravasation, as well as to strengthen the judgment of delayed skin toxicity of chemotherapeutic drugs. Rupture of the PICC in the lower extremities was primarily attributed to the use of a silicone catheter and an excessive puncture angle. The nature of docetaxel and partial catheter rupture caused drug extravasation, leading to delayed skin toxicity. The use of a polyurethane catheter reduces the incidence of catheter rupture; hence, silicon catheters should be avoided. The central venous catheter is also at risk for the extravasation of chemotherapeutic agents. Moreover, docetaxel-induced delayed skin toxicity, which has a high incidence, should be treated as expected. Nurses and clinicians should be aware of PICC internal rupture and central venous catheter extravasation to strengthen the judgment of delayed skin toxicity of chemotherapeutic drugs.


Reference:

Tian T, Liu Y, Tan L. Delayed onset skin toxicity reaction after peripherally inserted central catheter rupture in lower extremities combined with chemotherapy. J Vasc Access. 2024 May 27:11297298241254640. doi: 10.1177/11297298241254640. Epub ahead of print. PMID: 38800966.